Realan Computer Products Company
|
Place of Origin: | Guangdong, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Black 12V 5A Computer AC Adapter , Desktop Power Adapter
High Quality Desktop Power adapter, Ac Adapter Realan E-12V5A-LR120050
Specification:
Model: |
E-Mini Adapter (12V 5A)-LR120050 |
Type: |
ITX Power, DC-ITX Power Adapter, LCD, LED Display Adapter and Laptop Adapter |
Parameter: |
1, Standard round mouth output interface: 2.5mm inner diameters, 5.5mm outer diameter; 12V output voltage, 60W output power |
1 DESCRIPTION:
The purpose of the document is to specify the functional requirements of a 60W switching power supply.
2 INPUT CHARACTERISTICS:
2.1 Input Voltage:
Rated Voltage: 100~240Vac
Variation Range: 90-280Vac
2.2 Input Frequency:
Rated Frequency: 50/60Hz
Variation Frequency: 47-63Hz
2.3 Input Current:
1.6Amps max at any input voltage and rated, DC output rated load.
2.4 Inrush Current:
120 Amps Max Cold start at 240Vac input, with rated load and 25 ambient.
2.5 Ac Leakage Current:
0.25mA Max.At240Vac input.
3 OUTPUT CHARACTERISTICS:
3.1 Power output
Voltage |
Min. Load |
Rated. Load |
Stand by power |
Output power |
12Vdc |
0.01A |
5.0A |
0.5W Max |
60W |
3.2 Combined Load/Line Regulation
Voltage |
Min. Load |
Rated. Load |
Line Regulation |
Load Regulation |
12Vdc |
0.01A |
5.0A |
±1% |
±5% |
3.3 Ripple and Noise:
Under nominal voltage and nominal load, the ripple and noise are as follows when measure with Max. Bandwidth of 20MHz and Parallel 47uF/0.1uF, crossed connected at testing point.
Voltage Ripple and Noise (Max)
+12Vdc 120mV p-p
3.4 Turn on delay time:
3Second Max at 115Vac input and output Max load
3.5 Rise time:
40 mS Max at 115Vac input and output Max load
3.6 Hold up time:
5 mS Min at 115Vac input and output Max Load
3.7 Efficiency:
75% Min, At 115/230Vac input voltage,1/4,1/2,3/4 and full load calculation average efficiency
4 PROTECTION FUNCTION:
4.1 Short circuit test:
The power supply will be auto recovered when short circuit faults remove.
4.2 Over current Protection:
The power supply will be auto recovered when over current faults remove.
4.3 Over Voltage Protection:
The power supply will auto recovered when faults remove 120%~170%.
5 ENVIRONMENTAL REQUIREMET:
5.1 Operating Temperature:
0 to 40,Full load, Normal operation.
5.2 Storage Temperature:-20 to 80 With package
5.3 Relative Humidity:
5%(0)~90%(40)RH,72Hrs,Full load, Normal operating.
5.4 Vibration:
Operating: IEC 721-3-3 3M3
5~9Hz, A=1.5mm
(9~200Hz, Acceleration 5m/S2)
Transportation:
IEC 721-3-2 2M2
5-9Hz, A=3.5mm
9~200Hz, Acceleration=5m/S2
200~500Hz, Acceleration=15m/S2
Axes, 10 cycles per axis
No permanent damage may occur during testing.
The SAMPLE has to restore to its original situation after power off/on.
5.5 Dropping Packed:
1M for wall mount type and 760mm for desktop type as above described.
The horizontal surface consists of hardwood at least 13mm thick, mounted on two layers of plywood each 19mm to 20mm thick, all supported on a concrete or equivalent non-resilient floor.
6 SAFETY REQUIREMENT:
6.1 TUV/GS-(EN60950-1), CCC-(GB4943) AS/NZS: 60950-1, UL/CUL-(UL60950-1)
Safety: accord with TUV/GS-(EN60950-1), CCC-(GB4943) AS/NZS: 60950-1, UL/CUL-(UL60950-1)
6.2 DIELECTRIC STRENGTH Hi-Pot:
Primary to secondary: 1800Vac10mA/3S for type test.
6.3 Insulation resistance:
Primary to secondary: 10MΩ min at 500V DC.
6.4 EMI STANDARD
Meets the Limits of
<1>. Fcc part15 class B rules
<2>. EN55022 class B rules
<3>. GB9254-1998, GB17625.1-2003